Technical information ...
 
 
THE CHEMICAL ANALYSIS OF THE LIMESTONE AND MINERALS

RADIATION AND SANITARY CONCLUSION
TEST PROTOCOL

 


  









TEST PROTOCOL







     

   
 

TEST CENTER “EXPERT BUREAU “CRIMEA-SOYUZ-STANDARD”, LLC
Certificate of accreditation № RE 1712/2004, registered on December 30, 2004.
34/2, Kievskaya Str., Simferopol, 95017

TEST PROTOCOL
№ 16p
of August 22, 2005

Test center “Expert bureau “Crimea – Soyuz – Standard”, LLC tested natural rock wall blocks of IR 100 mark, State Standard of Ukraine (GOST) 4001-84 (N) with the aim of periodical tests.

Tests were carried out from June 8, 2005 till August 22, 2005.

  1. The ordering company: “Alminski Building Materials Factory” Open Joint-Stock Company (OJSC), Bakhchisarai region, Skalistoe
  2. Grounds for tests: the contract
  3. Name and mark of products: natural rock wall blocks of IR 100 mark, GOST 4001-84 (N)

Identification and name of normative document: GOST 4001-84 “Natural rock wall blocks”. Specification/

  1. The manufacturer: “Alminski Building Materials Factory” Open Joint-Stock Company (OJSC), Bakhchisarai region, Skalistoe
  2. Sample is taken at “Alminski Building Materials Factory” Open Joint-Stock Company (OJSC), Bakhchisarai region, Skalistoe
  3. The act of sampling is of June 8, 2005
  4. The date of samples receiving: June 8, 2005
  5. The test site: Test center “Expert bureau “Crimea – Soyuz – Standard”, LLC, Simferopol
  6. Results of tests:

Parameter

Norms according to State Standard, Specifications

Actual results of tests

Admis sible error

Normative document for test method. State Standard

Workbook

1

2

3

4

5

6

Appearance and sizes of cubs-samples:
1. Geometrical parameters, mm, no more than

100x100x100

98x100x99

 

GOST 4001-84 p.1.1

№ 1

2. Compressive strength in dry, MP no less than

10,0

15,7

 

GOST 4001-84 p.1.3
GOST 8462-85

№ 2

3. Water absorption, %, no more than

30

12,6

 

GOST 4001-84 p.2.2
DSTU BV.2.7-42-97

-“-

4. Density, kg/m?, no more than

2100

1904

 

GOST 4001-84 p.2.2
DSTU BV.2.7-42-97

-“-

5. Frost resistance, cycles, no less than

35

35

 

GOST 4001-84 p.2.2
DSTU BV.2.7-42-97

№ 6

6. Compressive strength loss after freezing tests, % no more than

25

1,9

 

GOST 4001-84 p.2.2
DSTU BV.2.7-42-97

-“-

7. Weight loss of samples after freezing tests, %

 

0,3

 

GOST 4001-84 p.2.2
DSTU BV.2.7-42-97

-“-

Notice: test protocol is spread only to the samples, presented for tests.           